Battery R&D Equipment SINOPRO MAX

Home   >   Battery R&D Equipment   >   Battery Test analysis

Battery Test analysis

Product
Eight-channel battery test CT-4008T-5V6A-S1
Product No.
CT-4008T-5V6A-S1
Brand
SINOPROMRX

DESCRIPTION

Product name: Battery testing system CT-4008T-5V6A-S1

SPECIFICATION

Input AC

AC 220V/110V ±10% / 50Hz

Input power

425 W

Resolution

AD:16bit; DA:16bit

Input impedance

≥1MΩ

Voltage

CV output range

25mV~5V

Min discharge voltage

1V for universal holder,1.5V for 2m cable

Accuracy

± 0.05% FS

Stability

± 0.05% FS

Current

Output range/channel

Range1: 0.5mA-0.1A; Range2: 0.1A-3A; Range3: 3A-6A

Accuracy

± 0.05% FS

CV cut-off current

Range1: 0.2mA; Range2: 6mA; Range3: 12mA

Stability

± 0.05% FS

Power

Output power/channel

30W

Stability

± 0.1% FS

Time

Current response time

<1ms (10% FS~90% FS)

Working step time

≤(365*24)h/step Timeformat-00:00:00.000(h, m, s, ms)

Data record

 

 

Data record conditions

Min data record interval:100ms

Min voltage change: 10mV

Min current change: 0.2mA; 6mA; 12mA

Frequency

10Hz

Charge

Charge modes

CC, CV, CCCV, CP

Cut-off condition

Voltage, Current, Time, Capacity, Energy, -V

Discharge

Discharge modes

CC, CV, CCCV, CP, CR

Cut-off condition

Voltage, Current, Time, Capacity, Energy

Pulse

Charge

CC, CP

Discharge

CC, CP

Min pulse width

500ms

Pulse counts

Up to 32

Chg and Dschg switch

Supported

Cut-off condition

Voltage, Time

DCIR

Calculated DCIR values available in BTSDA

Cycle

Max cycles

65535

Max steps

254

Cycle nest

3

Protection

 

 

 

Safety protection

Power-failure data protection

Offline operation mode

User-defined protection conditions, such as upper and lower current/voltage, delay time, temperature, etc.

Channels feature

Independent pairs of closed loop for constant

Channels control mode

Independent control

Data acquisition method

Kelvin connection

Noise

<55dB

Database

MySQL

Communication

TCP/IP

Operating system

Windows 7/8/10 64bit

Data export

EXCEL, TXT, CSV, PDF, Plot/Graph

Min. disk drive

500GB

Communication port

Ethernet port

Leak Current

<5μA

Channels per unit

8

Operation and storage environment requirement

Operation environment temperature

0~40 (When the temperature is 25±10, the accuracy offset caused by temperature is less than 50ppm/)

Storage environment temperature

-10~50

Operation environment humidity

≤70% RH(no moisture condensation)

Storage environment humidity

≤80% RH(no moisture condensation)

Clamps and dimensions

Tester pictures

Clamps pictures

Universal holder

Alligator

Polymer

Ring connector

Pictures just for reference

Dimensions

(W*D*H)(mm)

3U19", 483*404*130

Warranty

One year limited warranty with lifetime support